Recommended Operating Conditions

(@T

A

= +25°C, unless otherwise specified.)

Symbol Characteristic Conditions

Min

Max

Unit

V

CC

Supply Voltage

Operating

4

28

V

T

A

Operating Ambient Temperature (Note 7)

Operating

-20

85

°C

Notes:

4. This application circuit can’t protect reverse coil current if power is connecting reverse.

5. I

o (con)

is 150 mA at +85°C.

6. See Performance Characteristics for other conditions.

7. Shall not exceed P

D

and Safety Operation Area.




Electrical Characteristics

(@T

A

= +25°C, unless otherwise specified.)

Symbol Characteristic

Conditions

Min

Typ.

Max

Unit

V

z

Output Zener Breakdown

Output Turn off

54

62

70

V

V

CE (SAT)

Output Saturation Voltage

V

CC

= 24V, I

C

= 400mA

1.1 1.5 V

I

CEX

Output Leakage Current

V

CE

= 24V, V

CC

= 24V

<

0.1

10

μA

I

CC

Supply Current

V

CC

= 24V, Output Open

5

10

mA

tr

Output Rise Time

V

CC

= 24V, RL = 820Ω, CL = 20pF

1.0 5

µs

tf Output

Falling

Time

V

CC

= 24V, RL = 820Ω, CL = 20pF

1.0 1.5

µs

t

Switch Time Differential

V

CC

= 24V, RL = 820Ω, CL = 20pF

3.0 10

µs




Test Circuit

266

CL1

CL2

24V

V

out

1 (DO)

V

out

2 (DOB)

RL1 = RL2 = 820 Ohm

CL1 = CL2 = 20 pF

RL2

RL1








Advertising