Ah920, Absolute maximum ratings, Recommended operating conditions – Diodes AH920 User Manual

Page 3

Advertising
background image

AH920

Document number: DS36768 Rev. 2 - 2

3 of 13

www.diodes.com

December 2013

© Diodes Incorporated

AH920

A Product Line of

Diodes Incorporated

Absolute Maximum Ratings

(Note 1)

Symbol

Parameter

Value

Unit

V

CC

Supply Voltage

20

V

I

CC

Supply Current (Fault)

5

mA

I

OUT

Output Current (Continuous)

25

mA

P

D

Power Dissipation

TO-92S-3

400

mW

SOT-23-3

230

T

A

Operation Temperature

-50 to +150

ºC

T

STG

Storage Temperature

-65 to +150

ºC

T

J

(Max)

Maximum Junction Temperature

+165

ºC

ESD

ESD (Human Body Model)

6000

V

Note 1: St

resses greater than those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and

functional operation of the device at these or any other conditions beyond those indicated under “Recommended Operating Conditions” is not implied.
Exposure to “Absolute Maximum Ratings” for extended periods may affect device reliability.






Recommended Operating Conditions


Symbol

Parameter

Min

Max

Unit

V

CC

Supply Voltage

3.5

20

V

T

A

Operating Ambient Temperature

-40

+125

ºC