New prod uc t ah1903, Recommended operating conditions, Electrical characteristics – Diodes AH1903 User Manual

Page 3

Advertising
background image

AH1903

Document number: DS36568 Rev. 2 - 2

3 of 12

www.diodes.com

January 2014

© Diodes Incorporated

NEW PROD

UC

T

AH1903



Recommended Operating Conditions

(@T

A

= +25°C, unless otherwise specified.)

Symbol Parameter

Conditions

Rating

Unit

V

DD

Supply Voltage

Operating

1.6V to 3.6V

V

T

A

Operating Temperature Range

Operating

-40 to +85

°C




Electrical Characteristics

(@T

A

= +25°C, V

DD

= 1.8V, unless otherwise specified.)

Symbol Parameter

Conditions Min

Typ

Max

Unit

V

OL

Output Low Voltage (on)

I

OUT

= 1mA

— 0.1 0.2 V

V

OH

Output High Voltage (off)

I

OUT

= -1mA

V

DD

-0.2 V

DD

-0.1

— V

SEL Low

Omnipolar operation selected

0

0.5

V

SEL High

Unipolar operation selected

1.4

3.6

V

R

U

SEL

BSEL pin internal pull-up resistor

(Note 7)

50 kΩ

Ioff Output

Leakage

Current

V

OUT

= 3.6V, Output off

< 0.1

1

µA

I

DD

(awake)

Supply Current

During ‘awake’ period,
T

A

= +25°C, V

DD

= 3V

2.1

mA

I

DD

(sleep)

During ‘sleep’ period,
T

A

= +25°C, V

DD

= 3V

2.5 —

mA

I

DD

(avg)

Average Supply Current

T

A

= +25°C, V

DD

= 1.8V

4.3 8 µA

T

A

= +25°C, V

DD

= 3.6V

7.2 13 µA

Tawake Awake

Time

(Note

8)

50 100 µs

Tperiod Period

(Note

8)

50 100 ms

D.C. Duty

Cycle

0.1 — %

Notes:

7. SEL pin internal pull-up resistor is only active during AWAKE time.
8. When power is initially on, the operating V

DD

(1.6V to 3.6V) must be applied to guarantee the output sampling.

The output state is valid after the second operating phase (typical 100ms).


Electrical Characteristics

(cont.)











Advertising