Ats137, Magnetic characteristics – Diodes ATS137 User Manual
Page 5
ATS137
SINGLE HALL EFFECT SWITCH
ATS137 Rev. 10
5 of 12
FEBRUARY 2010
DS31045
©
Diodes Incorporated
Magnetic Characteristics
(T
A
= 25
o
C, Note 7)
(1mT = 10 Gauss)
A grade
Symbol
Parameter
Min
Typ.
Max
Unit
Bops(south pole to brand side)
Operation Point
-
-
100
Gauss
Brps(south pole to brand side)
Release Point
10
-
-
Gauss
Bhy(
Brpx
Bopx
−
)
Hysteresis -
80
-
Gauss
B grade (for SIP-3L only)
Symbol
Parameter
Min
Typ.
Max
Unit
Bops(south pole to brand side) Operation
Point
-
-
130
Gauss
Brps(south pole to brand side)
Release Point
10
-
-
Gauss
Bhy(
Brpx
Bopx
−
)
Hysteresis -
80
-
Gauss
Notes: 7. Magnetic characteristics are for design information, which will vary with supply voltage, operating temperature and after soldering.