New prod uc t ah1806, Absolute maximum ratings, Recommended operating conditions – Diodes AH1806 User Manual

Page 3: Electrical characteristics

Advertising
background image

AH1806

Document number: DS36104 Rev. 4 - 2

3 of 10

www.diodes.com

February 2014

© Diodes Incorporated

NEW PROD

UC

T

AH1806

Absolute Maximum Ratings

(Note 6) @T

A

= +25°C, unless otherwise specified.)

Symbol Characteristics

Values

Unit

V

DD

Supply Voltage (Note 7)

7 V

V

OUT

Output Pin Voltage (Note 7)

7

V

V

DD REV

Reverse Supply Voltage

-0.3

V

V

OUT_REV

Reverse Output Pin Voltage

-0.3

V

I

OUTPUT

Output current (source and sink)

2.5

mA

B

Magnetic Flux Density

Unlimited

P

D

Package Power Dissipation

SC59 and SOT553

230

mW

Ts

Storage Temperature Range

-65 to +150

°C

T

J

Maximum Junction Temperature

150

°C

ESD HBM

Human Body Model ESD capability

6

kV

Notes:

6. Stresses greater than the 'Absolute Maximum Ratings' specified above may cause permanent damage to the device. These are stress ratings only;

functional operation of the device at these or any other conditions exceeding those indicated in this specification is not implied. Device reliability may be

affected by exposure to absolute maximum rating conditions for extended periods of time.

7. The absolute maximum V

DD

of 7V is a transient stress rating and is not meant as a functional operating condition. It is not recommended to operate the

device at the absolute maximum rated conditions for any period of time.


Recommended Operating Conditions

(@T

A

= +25°C, unless otherwise specified.)

Symbol Characteristic

Conditions

Rating Unit

V

DD

Supply Voltage

Operating

2.5 to 5.5

V

V

OUT_MAX

Maximum Output Pin Voltage

Operating

5.5

V

T

A

Operating Temperature Range

Operating

-40 to +85

°C



Electrical Characteristics

(@T

A

= +25°C, V

DD

= 3V, unless otherwise specified.)

Symbol Characteristic

Conditions

Min

Typ

Max

Unit

V

OUT_ON

Output On Voltage (V

OL

) I

OUT

= 1mA

— 0.1 0.3 V

Ioff Output

Leakage

Current

V

OUT

= 5.5V, Output off

< 0.1

1

µA

I

DD

(awake)

Supply Current

During ‘awake’ period,
T

A

= 25°C, V

DD

= 3V

— 3 6

mA

During ‘awake’ period,
T

A

= -40 to +85°C, V

DD

= 2.5V to 5.5V

— 3 12

mA

I

DD

(sleep)

During ‘sleep’ period,
T

A

= +25°C, V

DD

= 3V

— 5 10

µA

I

DD

(sleep)

During ‘sleep’ period,
T

A

= -40 to +85°C, V

DD

= 2.5V to 5.5V

— — 28

µA

I

DD

(avg)

Average Supply Current

T

A

= +25°C, V

DD

= 3V

— 8 16

µA

T

A

= -40 to +85°C, V

DD

= 2.5V to 5.5V

— — 40

µA

Tawake Awake

Time

(Note

8)

75 125 µs

Tperiod Period

(Note

8)

75 125 ms

D.C. Duty

Cycle

— 0.1 — %

Note:

8. When power is initially turned on, the operating V

DD

must be within its correct operating range (2.5V to 5.5V) to guaranteed the output sampling.

The output state is valid after the second operating cycle (typical 150ms).