Ah1812 new prod uc t, Absolute maximum ratings, Recommended operating conditions – Diodes AH1812 User Manual

Page 3: Electrical characteristics

Advertising
background image

AH1812

Document number: DS36171 Rev. 2 - 2

3 of 8

www.diodes.com

August 2013

© Diodes Incorporated

AH1812

NEW PROD

UC

T

Absolute Maximum Ratings

(Note 6) (@T

A

= +25°C, unless otherwise specified.)

Symbol Characteristics

Values

Unit

V

DD

Supply Voltage (Note 7)

6

V

V

DD_REV

Reverse Supply Voltage

-0.3

V

I

OUTPUT

Output current (source and sink)

2

mA

B

Magnetic Flux Density

Unlimited

P

D

Package Power Dissipation

X1-DFN1216-4

230

mW

Ts

Storage Temperature Range

+150

°C

T

J

Maximum Junction Temperature

150

°C

ESD HBM

Human Body Model ESD capability

4

kV

Notes:

6. Stresses greater than the 'Absolute Maximum Ratings' specified above may cause permanent damage to the device. These are stress ratings only;

functional operation of the device at these or any other conditions exceeding those indicated in this specification is not implied. Device reliability may be

affected by exposure to absolute maximum rating conditions for extended periods of time.

7. The absolute maximum V

DD

of 6V is a transient stress rating and is not meant as a functional operating condition. It is not recommended to operate the

device at the absolute maximum rated conditions for any period of time.



Recommended Operating Conditions

(@T

A

= +25°C, unless otherwise specified.)

Symbol Characteristic

Conditions

Rating Unit

V

DD

Supply Voltage

Operating

1.6 to 3.6

V

T

A

Operating Temperature Range

Operating

-40 to +85

C




Electrical Characteristics

(@T

A

= +25°C, V

DD

= 3V, unless otherwise specified.)

Symbol Characteristic

Conditions

Min

Typ

Max

Unit

V

OUT

Output Low Voltage (on)

I

OUT

= 1mA

— 0.1

0.2 V

Ioff

Output leakage current

Vout=3.6V, B < Brps

<0.1

1

µA

I

DD

(awake)

Supply Current

During ‘awake’ period

2.3

mA

I

DD

(sleep)

During ‘sleep’ period

2.5

µA

I

DD

(avg)

Average Supply Current

V

DD

= 1.85V

— 4.3 8 µA

I

DD

(avg) V

DD

= 3.0V

— 6 10

µA

Tawake

Awake Active Pulse Width

(Note 8)

50

100

µs

Tperiod

Awake Period

(Note 8)

50

100

ms

D.C. Duty

Cycle

— 0.1 — %

Note:

8. When power is initially turned on, the operating V

DD

(1.6V to 3.6V) must be applied to guaranteed the output sampling.

The output state is valid after the second operating cycle (typical 100ms).

Advertising