New prod uc t ah1893, Magnetic characteristics – Diodes AH1893 User Manual

Page 4

Advertising
background image

AH1893

Document number: DS35740 Rev. 1 - 2

4 of 10

www.diodes.com

July 2013

© Diodes Incorporated

NEW PROD

UC

T

AH1893

Magnetic Characteristics

(Note 9 &10) (T

A

= +25°C, V

DD

= 1.85V, unless otherwise specified)

(1mT=10 Gauss)

Symbol Characteristics

Test

Condition

Min

Typ

Max

Unit

Bops (south pole to part marking side)

Operation Point

T

A

= +25

C

16 30 42

Gauss

T

A

= -40°C to +85

C

14 30 46

Bopn (north pole to part marking side)

T

A

= +25

C

-42 -30 -16

T

A

= -40°C to +85

C

-46 -30 -14

Brps (south pole to part marking side)

Release Point

T

A

= +25

C

10 20 35

T

A

= -40°C to +85

C

9 20 39

Brpn (north pole to part marking side)

T

A

= +25

C

-35 -20 -10

T

A

= -40°C to +85

C

-39 -20 -9

Bhy (|Bopx|-|Brpx|)

Hysteresis (Note 11)

T

A

= +25

C

5 10 15

T

A

= -40°C to +85

C

- 10 -

Notes:

9. Typical data is at T

A

= +25

C, V

DD

= 1.85V.

10. Maximum and minimum parameters values over the operating temperature range are not tested in production, they are guaranteed by design, process

control and characterization. The magnetic characteristics may vary with supply voltage, operating temperature and after soldering.

11. Maximum and minimum hysteresis is guaranteed by design and characterization.