Absolute Maximum Ratings

(Note 6) (@T

A

= +25°C, unless otherwise specified.)

Symbol Parameter

Rating

Unit

V

DD

Supply Voltage (Note 7)

6 V

V

DD_REV

Reverse

Supply

Voltage

-0.3

V

I

OUTPUT

Output current (source and sink)

3

mA

B

Magnetic Flux Density

Unlimited

P

D

Package

Power

Dissipation

X1-DFN1216-4 230

mW

X2-DFN2015-6 230

mW

Ts

Storage Temperature Range

-65 to +150

°C

T

J

Maximum Junction Temperature

150

°C

ESD HBM

Human Body Model (HMB) ESD capability

8

kV

Notes:

6. Stresses greater than the 'Absolute Maximum Ratings' specified above may cause permanent damage to the device. These are stress ratings only;

functional operation of the device at these or any other conditions exceeding those indicated in this specification is not implied. Device reliability may be

affected by exposure to absolute maximum rating conditions for extended periods of time.

7. The absolute maximum V

DD

of 6V is a transient stress rating and is not meant as a functional operating condition. It is not recommended to

operate the device at the absolute maximum rated conditions for any period of time.



Recommended Operating Conditions

(@T

A

= +25°C, unless otherwise specified.)

Symbol Parameter

Conditions

Rating

Unit

V

DD

Supply Voltage

Operating

1.6V to 3.6V

V

T

A

Operating Temperature Range

Operating

-40 to +85

°C



Electrical Characteristics

(@T

A

= +25°C, V

DD

= 1.8V, unless otherwise specified.)

Symbol Parameter

Conditions Min

Typ

Max

Unit

V

OL

Output Low Voltage (on)

I

OUT

= 1mA

0.1

0.2

V

V

OH

Output High Voltage (off)

I

OUT

= -1mA

V

DD

-0.2 V

DD

-0.1 —

V

Ioff Output

Leakage

Current

V

OUT

= 3.6V, Output off

< 0.1

1

µA

I

DD

(awake)

Supply Current

During ‘awake’ period,
T

A

= +25°C, V

DD

= 3V

2.1 — mA

I

DD

(sleep)

During ‘sleep’ period,
T

A

= +25°C, V

DD

= 3V

2.5 — µA

I

DD

(avg) Average

Supply

Current

T

A

= +25°C, V

DD

= 1.8V

4.3 8 µA

T

A

= +25°C, V

DD

= 3.6V

7.2 13 µA

Tawake Awake

Time

(Note

8)

50 100 µs

Tperiod Period

(Note

8)

50 100 ms

D.C. Duty

Cycle

0.1 — %

Note:

8. When power is initially turned on, the operating V

DD

(1.6V to 3.6V) must be applied to guaranteed the output sampling.

The output state is valid after the second operating cycle (typical 100ms).