Data sheet, Recommended operating conditions (t, 25 ° c) – Diodes AH49H User Manual

Page 4

Advertising
background image


Data Sheet

LINEAR HALL EFFECT IC AH49H

Jun. 2013 Rev. 1.2 BCD Semiconductor Manufacturing Limited

Absolute Maximum Ratings (Note 1)

Parameter Symbol

Value

Unit

Supply Voltage

V

CC

10

V

Instantaneous Supply Voltage

V

CC_INST

50

V

Power Dissipation

TO-92S-3

P

D

400

mW

SOT-23-3 230

Ambient Temperature

T

A

-40

to

125

°C

Storage Temperature

T

STG

-50

to

150

°C

ESD (Human Body Model)

6000

V

ESD (Machine Mode)

400

V

Note 1: Stresses greater than those listed under “Absolute Maximum Ratings” may cause permanent damage to
the device. These are stress ratings only, and functional operation of the device at these or any other conditions
beyond those indicated under “Recommended Operating Conditions” is not implied. Exposure to “Absolute
Maximum Ratings” for extended periods may affect device reliability.




Recommended Operating Conditions (T

A

=25

°C)

Parameter

Symbol Min

Max Unit

Supply Voltage

V

CC

3

8

V

Operating Temperature

T

OP

-40

105

°C









Advertising