Preliminary datasheet, Recommended operating conditions, Electrical characteristics – Diodes AP2602 User Manual
Page 5: Parameter symbol min max unit, Parameter symbol conditions min typ max units
Preliminary Datasheet
Octave Remote Resistor-programmable Temperature Switches AP2602
Feb. 2012 Rev. 1. 0 BCD Semiconductor Manufacturing Limited
5
Recommended Operating Conditions
Parameter
Symbol Min
Max Unit
Supply Voltage
V
CC
2.7
5.5
V
Operating Ambient Temperature
Range
T
A
-40 125
°C
Electrical Characteristics
V
CC
=2.7V to 5.5V, T
A
=-40°C to 125°C, unless otherwise specified. Typical values are at T
A
=25°C.
Parameter Symbol Conditions Min
Typ
Max
Units
Supply Voltage
V
CC
2.7 5.5 V
V
TMSNSX
=V
CC
40
100
Supply Current
I
CC
V
CC
=3.3V
OTXY
__________
float
V
TMSNSX
=GND
55
110
µA
V
CC
=5V, V
SEL
=V
CC,
V
TH
/V
CC
0.244
0.25
0.256
TMSNSX Input
Threshold
V
TH
/V
CC
V
CC
=3.3V, V
SEL
=V
CC,
V
TH
/V
CC
0.24 0.25 0.26
V/V
VTRIG Input Range
V
TRIG
0<V
TRIG
<0.4×V
CC
0.5
0.4×
V
CC
V
Offset Voltage
between VTRIG and
TMSNSX
V
OS
V
CC
=5V, V
SEL
=GND -15
15
mV
V
IH
V
CC
=5V 2
V
SEL Input Voltage
V
IL
V
CC
=5V
1
V
Open-drain OTXY
__________
Output Sink Current
I
SINK
V
OT
=0.3V, V
TMSNSX
=0V 3
4.5
mA
Open-drain OTXY
__________
Output Leakage
Current
I
LEAK-OT
V
OT
=V
CC
, V
TMSNSX
=5V
1
µA
Thermal Resistance
θ
JC
QFN-3X3-16
4.2
°C/W