Voltage detector az70xx data sheet, Recommended operating conditions – Diodes AZ70XX User Manual

Page 4

Advertising
background image

4

BCD Semiconductor Manufacturing Limited

VOLTAGE DETECTOR AZ70XX

Data Sheet

Oct. 2011 Rev. 2. 2

Note 1:

Stresses greater than those listed under "Absolute Maximum Ratings" may cause permanent damage to

the device. These are stress ratings only, and functional operation of the device at these or any other conditions
beyond those indicated under"Recommended Operating Conditions" is not implied. Exposure to "Absolute Maxi-
mum Ratings" for extended periods may affect device reliability.

Recommended Operating Conditions

Parameter Symbol

Value

Unit

Supply Voltage

V

CC

-0.3 to 20

V

Power Dissipation (Package Limitations,
T

A

=25

o

C)

P

D

TO-92 Package: 400

mW

SOT-89 Package: 500

Operating Junction Temperature

T

J

150

o

C

Storage Temperature Range

T

STG

-65 to 150

o

C

Parameter

Symbol

Min

Max

Unit

Supply Voltage

V

CC

18

V

Operating Temperature Range

T

A

-40

85

o

C

Absolute Maximum Ratings (Note 1)