Recommended operating conditions – Diodes 74AUP2G04 User Manual

Page 3

Advertising
background image

74AUP2G04

Document number: DS35509 Rev. 2 - 2

3 of 11

www.diodes.com

December 2013

© Diodes Incorporated

74AUP2G04

NEW PROD

UC

T



Recommended Operating Conditions

(Note 5) (@T

A

= +25°C, unless otherwise specified.)

Symbol Parameter

Min

Max

Unit

V

CC

Operating Voltage

0.8 3.6 V

V

I

Input Voltage

0 3.6

V

V

O

Output Voltage

0

V

CC

V

I

OH

High-Level Output Current

V

CC

= 0.8V

-20

µA

V

CC

= 1.1V

-1.1

mA

V

CC

= 1.4V

-1.7

V

CC

= 1.65V

-1.9

V

CC

= 2.3V

-3.1

V

CC

= 3.0V

-4

I

OL

Low-Level Output Current

V

CC

= 0.8V

20

µA

V

CC

= 1.1V

1.1

mA

V

CC

= 1.4V

1.7

V

CC

= 1.65V

1.9

V

CC

= 2.3V

3.1

V

CC

= 3.0V

4

∆t/∆V

Input Transition Rise or Fall Rate

V

CC

= 0.8V to 3.6V

200

ns/V

T

A

Operating Free-Air Temperature

-40 125

°C

Note:

5. Unused inputs should be held at V

CC

or Ground.