Operating characteristics, Parameter measurement information – Diodes 74AUP2G06 User Manual

Page 6

Advertising
background image

74AUP2G06

Document number: DS35510 Rev. 2 - 2

6 of 11

www.diodes.com

December 2013

© Diodes Incorporated

74AUP2G06

NEW PROD

UC

T


Operating Characteristics

(@T

A

= +25°C, unless otherwise specified.)

Parameter

Test

Conditions

V

CC

Typ Unit

C

pd

Power Dissipation Capacitance

f = 1MHz
No Load

0.8V 0.3

pF

1.2V ± 0.1V

0.4

1.5V ± 0.1V

0.5

1.8V ± 0.15V

0.5

2.5V ± 0.2V

0.5

3.3V ± 0.3V

0.6

C

I

Input Capacitance

V

I

= V

CC

or GND

0V or 3.3V

2.0

pF

C

O

Output Capacitance

V

O

= V

CC

or GND

0V

2.0

pF


Parameter Measurement Information

TEST

Condition

t

PLZ

(see Notes D and E)

t

PZL

(see Notes D and F)

Vload
Vload


V

CC

Inputs

V

M

V

LOAD

C

L

R

L

V∆

V

I

t

r

/t

f

0.8V

V

CC

≤3 ns

V

CC

/2

2 X V

CC

5, 10, 15, 30pF

5kΩ 0.1V

1.2V±0.1V

V

CC

≤3 ns

V

CC

/2

2 X V

CC

5, 10, 15, 30pF

5kΩ 0.1V

1.5V±0.1V

V

CC

≤3 ns

V

CC

/2

2 X V

CC

5, 10, 15, 30pF

5kΩ 0.15V

1.8V±0.15V

V

CC

≤3 ns

V

CC

/2

2 X V

CC

5, 10, 15, 30pF

5kΩ 0.15V

2.5V±0.2V

V

CC

≤3 ns

V

CC

/2

2 X V

CC

5, 10, 15, 30pF

5kΩ 0.15V

3.3V±0.3V

V

CC

≤3 ns

V

CC

/2

2 X V

CC

5, 10, 15, 30pF

5kΩ 0.3V

Voltage Waveform Pulse Duration


Voltage Waveform Propagation Delay Times

Figure 1. Load Circuit and Voltage Waveforms

Notes: A. Includes test lead and test apparatus capacitance.

B. All pulses are supplied at pulse repetition rate ≤ 10MHz

C. The inputs are measured one at a time with one transition per measurement.
D. For the open drain device t

PLZ

and t

PZL

are the same as t

PD

E. t

PZL

is measured at V

M

.

D. t

PLZ

is measured at V

OL

+V

.

Advertising