Switching characteristics, Operating characteristics, Parameter measurement information – Diodes 74AHCT138 User Manual

Page 5

Advertising
background image

74AHCT138

Document number: DS35483 Rev. 2 - 2

5 of 9

www.diodes.com

June 2013

© Diodes Incorporated

74AHCT138


Switching Characteristics

Symbol

Parameter

Test Conditions

V

CC

T

A

= +25°C

-40°C to +85°C

-40°C to +125°C

Unit

Min Typ Max Min

Max Min Max

t

PD

Propagation Delay
An to Yn

Figure 2 C

L

=15pF

4.5V to 5.5V

0.5

4.4

10.4

1.0

12.0

1.0

13.0

ns

Figure 2 C

L

= 50pF

4.5V to 5.5V

0.5

6.2

11.4

1.0

13.0

1.0

14.5

Propagation Delay
E3 to Yn

Figure 2 C

L

= 15pF

4.5V to 5.5V

0.5

4.3

9.1

1.0

10.5

1.0

11.5

ns

Figure 2 C

L

= 50pF

4.5V to 5.5V

0.5

6.2

10.1

1.0

11.5

1.0

13.0

Propagation Delay
En to Yn

Figure 2 C

L

= 15pF

4.5V to 5.5V

0.5

4.3

9.6

1.0

11.0

1.0

12.0

ns

Figure 2 C

L

= 50pF

4.5V to 5.5V

0.5

6.2

10.6

1.0

12.0

1.0

13.5


Operating Characteristics

(@T

A

= +25°C, unless otherwise specified.)

Parameter

Test

Conditions

V

CC

= 5V

Unit

Typ

C

pd

Power dissipation

capacitance

f = 1 MHz all outputs switching-no load

23

pF

Parameter Measurement Information

V

CC

Inputs

V

M

C

L

V

I

t

r

/t

f

Input Output

4.5V to 5.5V

3.0 V

3ns

1.5 V

V

CC

/2

15pF, 50pF

Voltage Waveform

Pulse Duration

Voltage Waveform

Propagation Delay Times

Inverting and Non Inverting Outputs

Notes: A. Includes test lead and test apparatus capacitance.

B. All pulses are supplied at pulse repetition rate

10 MHz.

C. Inputs are measured separately one transition per measurement.

D. t

PLH

and t

PHL

are the same as t

PD

.

Advertising