Recommended operating conditions, Electrical characteristics – Diodes 74AHCT594 User Manual

Page 4

Advertising
background image

74AHCT594

Document number: DS35485 Rev. 2 - 2

4 of 10

www.diodes.com

June 2013

© Diodes Incorporated

74AHCT594

Recommended Operating Conditions

(Note 5) (@T

A

= +25°C, unless otherwise specified.)

Symbol Parameter

Conditions

Min

Max

Unit

V

CC

Supply Voltage

4.5 5.5 V

V

I

Input Voltage

0 5.5

V

V

O

Output Voltage

Active Mode

0

V

CC

V

t/V

Input transition Rise or Fall Rate

V

CC

= 4.5V to 5.5V

20 ns/V

T

A

Operating Free-Air Temperature

-40 +125

°C

Note:

5. Unused inputs should be held at V

CC

or Ground.


Electrical Characteristics

(@T

A

= +25°C, unless otherwise specified.)

Symbol Parameter Test

Conditions

V

CC

T

A

= +25°C

T

A

= -40°C to +85°C T

A

= -40°C to +125°C

Unit

Min Typ Max Min

Max

Min

Max

V

IH

High-level Input
Voltage

4.5V to 5.5V

2.0

2.0

2.0

V

V

IL

Low-level input
voltage

4.5V to 5.5V

0.8

0.8

0.8 V

V

OH

High Level
Output Voltage

I

OH

= -50

μA

4.5V 4.4

4.5

4.4

4.4

V

I

OH

= -8mA

4.5V 3.94

3.80

3.70

V

OL

Low-level
Output Voltage

I

OL

= 50

μA

4.5V

0 0.1

0.1

0.1

V

I

OL

= 8mA

4.5V

0.36

0.44

0.55

I

I

Input Current

V

I

= GND or 5.5V

0V to 5.5V

0.1 ±0.1

± 1

± 2

μA

I

CC

Supply Current

V

I

= GND or V

CC

I

O

= 0

5.5V

4.0

40

80

μA

∆I

CC

Additional
Supply Current
per Input

V

I

= V

CC

-2.1V

I

O

= 0

4.5V to 5.5V

1.35

1.5

1.5 mA

C

i

Input
Capacitance

V

i

= V

CC

or GND

5.5V

3.5 10

10

10 pF


































Advertising