Absolute maximum ratings, Recommended operating conditions – Diodes 74HC595 User Manual

Page 4

Advertising
background image

74HC595

Document number: DS35492 Rev. 3 - 2

4 of 11

www.diodes.com

June 2013

© Diodes Incorporated

74HC595


Absolute Maximum Ratings

(Note 4)

(@T

A

= +25°C, unless otherwise specified.)

Symbol

Description

Rating

Unit

ESD HBM

Human Body Model ESD Protection

2

kV

ESD CDM

Charged Device Model ESD Protection

1

kV

ESD MM

Machine Model ESD Protection

200

V

V

CC

Supply Voltage Range

-0.5 to +7.0

V

V

I

Input Voltage Range

-0.5 to +7.0

V

V

o

Voltage applied to output in high or low state

-0.3 to V

CC

+0.5

V

I

IK

Input Clamp Current V

I

< -0.5V

-20 mA

I

IK

Input Clamp Current VI > Vcc +0.5V

20

mA

I

OK

Output Clamp Current V

O

<-0.5V

-20 mA

I

OK

Output Clamp Current V

O

> V

CC

+0.5V

20 mA

I

O

Continuous output current

Q7 standard output

±25

mA

Qn bus driver outputs

±35

mA

I

CC

Continuous current through Vdd or GND

70

mA

I

GND

Continuous current through Vdd or GND

-70

mA

T

J

Operating Junction Temperature

-40 to +150

°C

T

STG

Storage Temperature

-65 to +150

°C

P

TOT

Total Power Dissipation

500

mW

Note:

4. Stresses beyond the absolute maximum may result in immediate failure or reduced reliability. These are stress values and device operation should be

within recommend values.


Recommended Operating Conditions

(Note 5) (@T

A

= +25°C, unless otherwise specified.)

Symbol Parameter

Conditions

Min

Max Unit

V

CC

Supply Voltage

2.0 6.0

V

V

I

Input Voltage

0

V

CC

V

V

O

Output Voltage

Active Mode

0

V

CC

V

Δt/ΔV

Input transition rise or fall rate

V

CC

= 2.0V

1000

ns/V

V

CC

= 4.5V

500

V

CC

= 6.0V

400

T

A

Operating free-air temperature

-40 +125 °C

Note:

5. Unused inputs should be held at V

CC

or Ground.























Advertising