74HCT125

Document number: DS35336 Rev. 3 - 2

4 of 8

www.diodes.com

January 2013

© Diodes Incorporated

74HCT125


Switching Characteristics

Symbol

Parameter

Test Conditions

V

CC

T

A

= +25°C

-40°C to +85°C

-40°C to +125°C

Unit

Min Typ Max

Max

Max

t

PD

Propagation

Delay A

N

to Y

N

Figure 1

C

L

= 50pF

4.5V

— 15 25

31

38

ns

t

EN

Enable Time

OE

N

to Y

N

— 15 28

35

42

ns

t

DIS

DisableTime

OE

N

to Y

N

— 15 25

31

38

ns

t

t

Transition Time

5

12

15

18

ns


Operating Characteristics

(@T

A

= +25°C, unless otherwise specified.)

Parameter Test

Conditions

V

CC

= 5.5V

Unit

Typ

C

pd

Power Dissipation

Capacitance per Gate

f = 1 MHz

24

pF

C

I

Input Capacitance

V

I

= V

CC

– or GND

3.5 pF


Parameter Measurement Information

V

CC

Inputs

V

M

V

LOAD

C

L

R

L

V∆

V

I

t

r

/t

f

4.5V 1.5V

≤6ns 3.0V 2 X V

CC

50pF 2KΩ

10% of V

CC

Voltage Waveform

Pulse Duration

Voltage Waveform

Propagation Delay Times


Notes:

A. Includes test lead and test apparatus capacitance.

B. All pulses are supplied at pulse repetition rate ≤ 1 MHz

C. The inputs are measured one at a time with one transition per measurement.

D. For the open drain device t

PLZ

and t

PZL

are the same as t

PD

E.

t

PZL

is measured at V

M

.

D.

t

PLZ

is measured at V

OL

+V

F. A Thevenin equivalent load may be used in place of V

CC

X 2 and resistor divider

Figure 1 Load Circuit and Voltage Waveforms

TEST Condition

t

PLZ

(see Notes D and E)

t

PZL

(see Notes D and F)

Vload
Vload

Advertising