74HCT138

Document number: DS35489 Rev. 3 - 2

4 of 10

www.diodes.com

June 2013

© Diodes Incorporated

74HCT138

Absolute Maximum Ratings

(Note 4)

(@T

A

= +25°C, unless otherwise specified.)

Symbol Description

Rating

Unit

ESD HBM

Human Body Model ESD Protection

2

KV

ESD CDM

Charged Device Model ESD Protection

1

KV

ESD MM

Machine Model ESD Protection

200

V

V

CC

Supply Voltage Range

-0.5 to 7.0

V

V

I

Input Voltage Range

-0.5 to 7.0

V

V

o

Voltage Applied to Output in High or Low State

-0.3 to V

CC

V

I

IK

Input Clamp Current V

I

< -0.5V

-20 mA

I

IK

Input Clamp Current V

I

> V

CC

+ 0.5V

20 mA

I

OK

Output Clamp Current V

O

< -0.5V

-20 mA

I

OK

Output Clamp Current V

O

> V

CC

+ 0.5V

20 mA

I

O

Continuous Output Current

+/- 25

mA

I

CC

Continuous Current Through V

CC

50 mA

I

GND

Continuous Current Through GND

-50

mA

T

J

Operating Junction Temperature

-40 to 150

°C

T

STG

Storage Temperature

-65 to 150

°C

P

TOT

Total Power Dissipation

500

mW

Note:

4. Stresses beyond the absolute maximum may result in immediate failure or reduced reliability. These are stress values and device operation should

be within recommend values.

Recommended Operating Conditions

(Note 5) (@T

A

= +25°C, unless otherwise specified.)

Symbol Parameter

Conditions

Min

Max

Unit

V

CC

Supply Voltage

4.5 5.5

V

V

I

Input Voltage

0 Vcc

V

V

O

Output Voltage

Active Mode

0

V

CC

V

t/V

Input transition rise or fall rate

V

CC

= 4.5V

100 ns/V

T

A

Operating free-air temperature

-40 125

°C

Note:

5. Unused inputs should be held at V

CC

or Ground.