Absolute maximum ratings, Recommended operating conditions – Diodes 74HCT595 User Manual

Page 4

Advertising
background image

74HCT595

Document number: DS35493 Rev. 3 - 2

4 of 11

www.diodes.com

July 2013

© Diodes Incorporated

Preliminary

74HCT595

Absolute Maximum Ratings

(Note 4) (@T

A

= +25°C°C, unless otherwise specified.)

Symbol

Description

Rating

Unit

ESD HBM

Human Body Model ESD Protection

2

kV

ESD CDM

Charged Device Model ESD Protection

1

kV

ESD MM

Machine Model ESD Protection

200

V

V

CC

Supply Voltage Range

-0.5 to +7.0

V

V

I

Input Voltage Range

-0.5 to +7.0

V

V

o

Voltage applied to output in high or low state

-0.3 to V

CC

+0.5

V

I

IK

Input Clamp Current V

I

< -0.5V

-20 mA

I

IK

Input Clamp Current V

I

> Vcc +0.5V

20 mA

I

OK

Output Clamp Current V

O

< -0.5V

-20 mA

I

OK

Output Clamp Current V

O

> V

CC

+ 0.5V

20 mA

I

O

Continuous output current

Q7 standard output

+/- 25

mA

Qn bus driver outputs

+/- 35

mA

I

CC

Continuous current through V

CC

or GND

70 mA

I

GND

Continuous current through V

CC

or GND

-70 mA

T

J

Operating Junction Temperature

-40 to +150

°C

T

STG

Storage Temperature

-65 to +150

°C

P

TOT

Total Power Dissipation

500

mW

Note:

4. Stresses beyond the absolute maximum may result in immediate failure or reduced reliability. These are stress values, and device

operation should be within recommend values.


Recommended Operating Conditions

(Note 5) (@T

A

= +25°C°C, unless otherwise specified.)

Symbol Parameter

Conditions

Min

Max

Unit

V

CC

Supply Voltage

4.5 5.5 V

V

I

Input Voltage

0 5.5 V

V

O

Output Voltage

Active Mode

0

V

CC

V

t/V

Input transition rise or fall rate

V

CC

= 4.5V to 5.5V

100 ns/V

T

A

Operating free-air temperature

-40 125 °C

Note: 5. Unused inputs should be held at V

cc

or Ground.





















Advertising