Absolute Maximum Ratings

(Note 4)

(@T

A

= +25°C, unless otherwise specified.)

Symbol

Description

Rating

Unit

ESD HBM

Human Body Model ESD Protection

2

KV

ESD CDM

Charged Device Model ESD Protection

1

KV

ESD MM

Machine Model ESD Protection

200

V

V

CC

Supply Voltage Range

-0.5 to 6.5

V

V

I

Input Voltage Range

-0.5 to 6.5

V

V

O

Voltage applied to output in high impedance or I

OFF

state

-0.5 to 6.5

V

V

O

Voltage applied to output in high or low state

-0.3 to V

CC

+0.5

V

I

IK

Input Clamp Current V

I

<0

-50 mA

I

OK

Output Clamp Current V

O

<0

-50 mA

I

O

Continuous output current

±50

mA

I

CC

,

,

I

GND

Continuous current through V

CC

or GND

±100 mA

T

J

Operating Junction Temperature

-40 to +150

°C

T

STG

Storage Temperature

-65 to +150

°C

P

TOT

Total Power Dissipation

500

mW

Note:

4. Stresses beyond the absolute maximum may result in immediate failure or reduced reliability. These are stress values and device operation should

be within recommend values.



Recommended Operating Conditions

(Note 5)

(@T

A

= +25°C, unless otherwise specified.)

Symbol Parameter

Conditions

Min

Max Unit

V

CC

Supply Voltage

1.65

5.50

V

V

I

Input Voltage

0

5.5

V

V

O

Output Voltage

Active Mode

0

V

CC

V

Vcc = 0V; Power Down Mode

0

5.5

V

Δt/ΔV

Input transition rise or fall rate

V

CC

= 1.65V to 2.7V

20

ns/V

V

CC

= 2.7V to 3.6V

10

T

A

Operating free-air temperature

-40

+125

°C

Note: