Single schmitt-trigger invereter, New prod uc t absolute maximum ratings, Recommended operating conditions – Diodes 74AHCT1G14 User Manual

Page 3

Advertising
background image

74AHCT1G14

SINGLE SCHMITT-TRIGGER INVERETER

74AHCT1G14

Document number: DS35183 Rev. 1 - 2

3 of 8

www.diodes.com

May 2011

© Diodes Incorporated

NEW PROD

UC

T

Absolute Maximum Ratings

(Note 2)

Symbol

Description

Rating

Unit

ESD HBM

Human Body Model ESD Protection

2

KV

ESD CDM

Charged Device Model ESD Protection

1

KV

ESD MM

Machine Model ESD Protection

200

V

V

CC

Supply Voltage Range

-0.5 to 6.5

V

V

I

Input Voltage Range

-0.5 to 6.5

V

V

O

Voltage applied to output in high or low state

-0.5 to V

CC

+0.5

V

I

IK

Input Clamp Current V

I

<0

-20 mA

I

OK

Output Clamp Current (V

O

< 0 or V

O

> V

CC

)

±20 mA

I

O

Continuous output current (V

O

= 0 to V

CC

)

±25 mA

I

CC

Continuous current through V

CC

50

mA

I

GND

Continuous current through GND

-50

mA

T

J

Operating Junction Temperature

-40 to 150

°C

T

STG

Storage Temperature

-65 to 150

°C

Notes: 2. Stresses beyond the absolute maximum may result in immediate failure or reduced reliability. These are stress values and device operation should be

within

recommend

values.

Recommended Operating Conditions

(Note 3)

Symbol

Parameter

Min

Max

Unit

V

CC

Operating Voltage

4.5

5.5

V

V

I

Input Voltage

0

5.5

V

V

O

Output Voltage

0

V

CC

V

I

OH

High-level output current

-8

mA

I

OL

Low-level output current

8

mA

Δt/ΔV

Input transition rise or fall rate

20

ns/V

T

A

Operating free-air temperature

-40

125

ºC

Notes: 3. Unused inputs should be held at V

CC

or Ground.

Advertising