Diodes 74LVC1G04 User Manual

Page 3

Advertising
background image

74LVC1G04

Document number: DS32198 Rev. 7 - 2

3 of 15

www.diodes.com

March 2014

© Diodes Incorporated

NEW PROD

UC

T

74LVC1G04

Absolute Maximum Ratings

(Notes 6, 7)

Symbol

Description

Rating

Unit

ESD HBM

Human Body Model ESD Protection

2

kV

ESD CDM

Charged Device Model ESD Protection

1

kV

ESD MM

Machine Model ESD Protection

200

V

V

CC

Supply Voltage Range

-0.5 to 6.5

V

V

I

Input Voltage Range

-0.5 to 6.5

V

V

O

Voltage Applied to Output in High Impedance or I

OFF

State

-0.5 to 6.5

V

V

O

Voltage Applied to Output in High or Low State.

-0.5 to V

CC

+0.5

V

I

IK

Input Clamp Current V

I

< 0

-50 mA

I

OK

Output Clamp Current

-50

mA

I

O

Continuous Output Current

±50

mA

I

CC

,

I

GN

Continuous Current Through V

CC

or GND

±100 mA

T

J

Operating Junction Temperature

-40 to +150

°C

T

STG

Storage Temperature

-65 to +150

°C

Notes:

6. Stresses beyond the absolute maximum may result in immediate failure or reduced reliability. These are stress values and device

operation should be within recommend values.

7. Forcing the maximum allowed voltage could cause a condition exceeding the maximum current or conversely forcing the maximum current could

cause a condition exceeding the maximum voltage. The ratings of both current and voltage must be maintained within the controlled range..

Advertising