background image

MBR10100CT / MBRF10100CT

Document number: DS36378 Rev. 8 - 2

2of 5

www.diodes.com

December 2013

© Diodes Incorporated

MBR10100CT / MBRF10100CT

ADVANCED INFORMATION



Maximum Ratings (Per Leg)

(@T

A

= +25°C, unless otherwise specified.)

Single phase, half wave, 60Hz, resistive or inductive load.
For capacitance load, derate current by 20%.

Characteristic Symbol

Value

Unit

Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage

V

RRM

V

RWM

V

RM

100 V

Average Rectified Output Current (Per Leg)
(Total)

I

O

5

10

A

Non-Repetitive Peak Forward Surge Current 8.3ms
Single Half Sine-Wave Superimposed on Rated Load

I

FSM

110 A





Thermal Characteristics (Per Leg)

Characteristic Symbol

Value

Unit

Typical Thermal Resistance, Junction to Case (Note 5)
Package = TO-220AB
Package = ITO-220AB

R

θJC

4
6

°C/W

Typical Thermal Resistance, Junction to Ambient (Note 5)
Package = TO-220AB
Package = ITO-220AB

R

θJA

16
30

°C/W

Operating and Storage Temperature Range

T

J

, T

STG

-55 to +175

°C





Electrical Characteristics (Per Leg)

(@T

A

= +25°C, unless otherwise specified.)

Characteristic Symbol

Min

Typ

Max

Unit

Test

Condition

Forward Voltage Drop

V

F


0.79

0.84
0.72

V

I

F

= 5A, T

A

= +25°C

I

F

= 5A, T

A

= +125°C

Leakage Current (Note 6)

I

R



0.05

10

mA

V

R

=100V, T

A

= +25°C

V

R

= 100V, T

A

= +125°C

Notes:

5. Device mounted on heatsink (45mm x 20mm x 12mm), with minimum recommended pad layout per http://www.diodes.com.
6. Short duration pulse test used to minimize self-heating effect.





















Advertising