Safe operating area, Derating curve, Transient thermal impedance – Diodes ZXTP2012Z User Manual
Page 3: Pulse power dissipation, Zxtp2012z, Thermal characteristics and derating information
![background image](/manuals/307722/3/background.png)
ZXTP2012Z
Da
tasheet Number: DS33713 Rev. 3 - 2
3 of 7
October 2012
© Diodes Incorporated
ZXTP2012Z
A Product Line of
Diodes Incorporated
Thermal Characteristics and Derating Information
100m
1
10
100
10m
100m
1
10
Single Pulse. T
amb
=25°C
25X25mm PCB 1oz copper
V
CE(sat)
Limit
100µs
1ms
10ms
100ms
1s
DC
Safe Operating Area
-I
C
Col
le
c
tor C
u
rrent
(A
)
-V
CE
Collector-Emitter Voltage (V)
0
20
40
60
80
100 120 140 160
0.0
0.5
1.0
1.5
2.0
2 5 X 2 5 m m P C B
1 oz cop per
5 0 X 5 0 m m P C B
1 oz copp er
Derating Curve
Temperature (°C)
M
a
x P
o
w
e
r Di
s
s
ipat
ion (
W
)
100µ
1m
10m 100m
1
10
100
1k
0
20
40
60
80
2 5 X 2 5 m m P C B 1 oz copp er
)
Transient Thermal Impedance
D=0.5
D=0.2
D=0.1
Single Pulse
D=0.05
Therm
a
l Res
is
tance
(°
C
/W)
Pulse Width (s)
100µ
1m
10m 100m
1
10
100
1k
1
10
100
Single Pulse. Tamb=25°C
25X25mm PCB 1oz copper
Pulse Power Dissipation
Pulse Width (s)
M
a
x P
o
w
e
r
Di
s
s
ipat
ion (W)