3. Install the stem over the drive pin in the impeller eye and tighten the locknut.
4. Set the stem to 0.004 in. (0.1 mm) TIR.
5. Install the diffuser.
6. Install the propeller and tighten the setscrews.
7. Use a new gasket and note the alignment pin when you install the assembly on the
suction housing.
8. Install the suction housing and discharge fasteners, and tighten.
Assemble the Series C17 and C35 pump
1
2
3
4
5
6
7
8
1.
Motor
2.
Water slinger
3.
Shaft
4.
Mechanical seal
5.
Impeller
6.
Wear ring
7.
Volute
8.
Motor bracket
Figure 3: Series C17