Position

Part

Description

2

Impeller

D-impeller
K-impeller

3

Mechanical seals

Type: Mechanical face seal

4

Oil housing

The oil housing includes a coolant that lubricates and cools the seals; the housing acts as a
buffer between the pumped fluid and the drive unit.

5

Main bearing

The bearing consisting of a two-row angular contact ball bearing.

6

Motor

For information about the motor, see .

Motor data

(page 44).

7

Stator housing

The pump is cooled by the ambient liquid/air.

8

Support bearing

The bearing consisting of a single-row ball bearing.

Monitoring Equipment

The following applies to the monitoring equipment of the pump:

• The stator incorporates thermal contacts connected in series that activates the alarm at

overtemperature.

• The thermal contacts open at 140°C (285°F).
• Ex-approved pumps must have thermal contacts connected to the control panel.
• The sensors must be connected to either the SMR 311 monitoring equipment or an

equivalent equipment.

• The monitoring equipment must be of a design that makes automatic restart

impossible.

• Information in the junction box shows if the pump is equipped with optional sensors

Optional sensors

LD LD is a miniature float switch for detection of liquid in the stator housing. Due to its

design it is best suited for pumps in a vertical position. The LD sensor is installed in the
bottom of the stator housing.

The data plate

The data plate

The data plate is a metal label located on the main body of the pump. The data plate lists
key product specifications.

Product Description

MK, MV (8202, 8202X) Installation, Operation, and Maintenance Manual

13

Advertising