Technical reference, Motor data, Motor data application limits – Bell & Gossett MK MV (8202, 8202X) User Manual
Page 46
Technical Reference
Motor data
Feature
Description
Motor type
Squirrel-cage induction motor
Frequency
60 Hz
Supply
1-phase or 3-phase
Starting method
Direct on-line
Maximum starts per
hour
30 evenly spaced starts per hour
Code compliance
IEC 60034-1
Rated output variation
±10%
Voltage variation without
overheating
±10%, provided that it does not run continuously at full load
Voltage imbalance
tolerance
2%
Stator insulation class
H (180°C [360°F])
Application limits
Data
Description
Liquid temperature
40°C (104°F) maximum
Liquid density
1100 kg/m³ (9.2 lb per US gal) maximum
pH of the pumped media
(liquid)
5.5–14
Depth of immersion
20 m (65 ft) maximum
Other
For the specific weight, current, voltage, power ratings, and speed of the pump, see
the data plate of the pump.
Technical Reference
44
MK, MV (8202, 8202X) Installation, Operation, and Maintenance Manual