Service item

Action

Support and main bearing

Replace the bearings with new bearings.

Mechanical seal

Replace with new seal units.

Service in case of alarm

For information about indication values for sensors, see

Sensor connection characteristics

(page 29).

Replace the impeller

WS000133A

Figure 10: D-impeller

WS000133A

Figure 11: K-impeller

Required tools:

• 8 mm hexagon bit adapter with an extension of at least 125 mm (4.92 in.)
• Impeller puller

If applicable, contact your local sales and service representative for correct type and
size.

• Rod (wooden or copper) for locking the impeller in place, if applicable.
• Two crowbars, if applicable

WARNING:
• If you fail with the impeller installation, you must redo the installation procedure from the

beginning.

• A worn impeller and/or pump housing can have very sharp edges. Wear protective

gloves.

• When laying the pump on its side, do not allow the weight of the pump to rest on any

portion of the impeller. The impeller must not be allowed to make contact with the
concrete floor or other hard and rough surfaces.

Remove the impeller: D, K

1. Remove the pump housing: