SAFETY
INSTRUCTIONS

This safety alert symbol will be used in this manual and on the
pump safety instruction decals to draw attention to safety related
instructions. When used the safety alert symbol means
ATTENTION! BECOME ALERT! YOUR SAFETY IS INVOLVED!
FAILURE TO FOLLOW THE INSTRUCTIONS MAY RESULT IN
A SAFETY HAZARD.

Your A-C 8100 Pump should have the following safety instruc-
tion decals displayed. If the decals are missing or illegible
contact your local G&L Pump representative for a replacement.

Additional Safety Requirements:

1. Electrical connections to be made by qualified Electrician in

accordance with all national, state and local codes.

2. Motor must have properly sized starter with properly sized

heaters to provide overload and undervoltage protection.

3. If pump, motor or piping are operating at extremely high or

low temperatures, guarding or insulation is required.

4. The maximum working pressure of the pump is listed on

the pump nameplate, do not exceed this pressure.

B. SAFETY INSTRUCTIONS

WARNING

ROTATING COMPONENTS

DISCONNECT AND LOCKOUT
POWER BEFORE SERVICING.
DO NOT OPERATE WITHOUT
ALL GUARDS IN PLACE.
CONSULT INSTALLATION
AND SERVICE INSTRUCTION
SHEET BEFORE OPERATING
OR SERVICING.
FAILURE TO FOLLOW
INSTRUCTIONS COULD
RESULT IN INJURY
OR DEATH.

P70642

WARNING

EYEBOLTS OR LIFTING
LUGS IF PROVIDED ARE
FOR LIFTING ONLY THE
COMPONENTS TO WHICH
THEY ARE ATTACHED.
FAILURE TO FOLLOW
INSTRUCTIONS COULD
RESULT IN INJURY
OR DEATH.

P70643

CAUTION

COUPLER ALIGNMENT IS
REQUIRED! LEVEL AND
GROUT PUMP BEFORE USE!
CHECK ALIGNMENT BEFORE
GROUTING, AFTER SYSTEM
IS FILLED, AFTER SERVICING
PUMP, AND AS REQUIRED.
CONSULT THE SERVICE
INSTRUCTIONS FOR DETAILS.
FAILURE TO FOLLOW THESE
INSTRUCTIONS COULD
RESULT IN INJURY OR
PROPERTY DAMAGE.

P70820

CAUTION

DO NOT RUN PUMP DRY,
SEAL DAMAGE MAY OCCUR.
INSPECT PUMP SEAL
REGULARLY FOR LEAKS,
REPLACE AS REQUIRED.
FOR LUBRICATION
REQUIREMENTS, CONSULT
SERVICE INSTRUCTIONS.
FAILURE TO FOLLOW
INSTRUCTIONS COULD
RESULT IN INJURY OR
PROPERTY DAMAGE.

P70644

Illustration 2 – Safety Instruction Decals

RATING PLATE

MODEL

NO.

SERIAL

NO.

IDENT.

NO.

G.P.M.

FT.

HP R.P.M.

P.S.I.

MAX.

WORK
PRESS.

1500

60

1780

G&L PUMP

G&L Pumps

A-C8100

14.8

LHR

CWP-11

8 x 8 x 17M

200

262

1-21937-1-1