Alignment MUST be checked prior to running. See

Figure 6.
Tighten all hold-down bolts before checking the align-

ment.
If realignment is necessary, always move the motor.

Shim as required.

Figure 6

Parallel misalignment (shafts with axis parallel but not

concentric). Place dial indicator on one hub and rotate

this hub 360º while taking readings on the outside di-

ameter of the other hub. Parallel alignment is achieved

when reading is 0.005” (0.127 mm) TIR, or less.
Angular misalignment (shaft with axis concentric but

not parallel). Place dial indicator on one hub and

rotate this hub 360º while taking readings on the face

of the other hub. Angular alignment is achieved when

reading is 0.005” (0.127 mm) TIR, or less.
Final alignment is achieved when parallel and angular

requirements are satisfied with motor hold-down bolts

tight.

NOTICE: ALWAYS RECHECK BOTH ALIGNMENTS

AFTER MAKING ANY MECHANICAL

ADJUSTMENTS.

ROTATION

NOTICE: INCORRECT ROTATION MAY CAUSE

DAMAGE TO THE PUMP AND VOIDS

THE WARRANTY.

Correct rotation is right-hand, CLOCKWISE when

viewed from the motor end. Remove motor end plug

or cover to observe rotation.
To reverse three phase motor rotation, interchange

any two power supply leads.

OPERATION

DO NOT OPERATE FRAME

MOUNTED UNITS WITHOUT SAFETY

GUARDS IN PLACE OR SEVERE

PERSONAL INJURY MAY RESULT.

SPLASHING OR IMMERSING OPEN

DRIP PROOF MOTORS IN FLUID

CAN CAUSE FIRE, SHOCK, BURNS

OR DEATH.

OPERATION AT OR NEAR ZERO

FLOW CAN CAUSE EXTREME HEAT,

PERSONAL INJURY OR PROPERTY

DAMAGE.

NOTICE: NO NOT RUN PUMP DRY OR SEAL

DAMAGE WILL RESULT.

After stabilizing the system at normal operating condi-

tions, check the piping. If necessary, adjust the pipe

supports.
On frame-mounted units, coupling alignment may

have changed due to the temperature differential

between pump and motor. Recheck alignment follow-

ing procedures and hazard warnings in “COUPLING

ALIGNMENT” section of this manual.

MAINTENANCE

FAILURE TO DISCONNECT AND

LOCKOUT ELECTRICAL POWER

BEFORE ATTEMPTING ANY

MAINTENANCE CAN CAUSE

SHOCK, BURNS OR DEATH.

FAILURE TO RELIEVE SYSTEM

PRESSURE AND DRAIN SYSTEM

BEFORE ATTEMPTING ANY

MAINTENANCE CAN CAUSE

PROPERTY DAMAGE, PERSONAL

INJURY OR DEATH.

Close-Coupled Units:
Bearings are located in and are part of the motor. For

lubrication information, refer to motor manufacturer’s

instructions.

Frame-Mounted Units:
Pump bearing frames have greased for life bearings.

No lubrication is possible or necessary.
Follow motor and coupling manufacturer’s lubrication

instructions.

WARNING

Hazardous voltage

can shock, burn or

cause death.

Extreme heat can

cause personal injury

or property damage.

WARNING

WARNING

Hazardous voltage

can shock, burn or

cause death.

Hazardous pressure can

cause personal injury or

property damage.

CAUTION

Hazardous machinery

can cause personal

injury or death.

WARNING