TROUBLESHOOTING

FAILURE TO DISCONNECT AND LOCKOUT ELECTRICAL

POWER BEFORE ATTEMPTING ANY MAINTENANCE

CAN CAUSE SHOCK, BURNS OR DEATH.

SYMPTOM:

Motor Not Running

See Probable Cause – 1 through 5

Little or No Liquid Delivered

See Probable Cause – 6 through 13

Excessive Power Consumption

See Probable Causes – 3, 13, 14, 15

Excessive Noise and Vibration

See Probable Causes – 3, 6, 7, 10, 12, 14, 16, 17

PROBABLE CAUSES:
1. Motor thermal protector tripped
2. Open circuit breaker or blown fuse
3. Impeller binding
4. Motor improperly wired
5. Defective motor
6. Pump is not primed, air or gases in pumpage
7. Discharge, suction plugged or valve closed
8. Incorrect rotation (3 phase only)
9. Low voltage or phase loss
10. Impeller worn or plugged
11. System head too high
12. NPSH

A

too low – Excessive suction lift or losses

13. Incorrect impeller diameter
14. Discharge head too low – excessive flow rate
15. Fluid viscosity, specific gravity too high
16. Worn bearing
17. Pump, motor or piping loose