WORKING LOAD LIMIT

Cable A10-12, A10-20 and A10-2015

The working load limit is based on a load being uniform-

ly applied in a straight line pull.

3

/

16

" 7x19 304SS Air Craft Cable WLL = 740 lbs.

Do not exceed safe working load limits.

WARNINGS

Inspection

Wire ropes, cables and attachments must all be inspected

regularly for visible damage or distortion, elongation,

corrosion, cracks, nicks or abrasion which may cause

failure or reduce the original strength or ability of the

products to perform safely. User must determine whether

future use of the wire rope or cable would constitute a

safety hazard to life or property.

Safety

Refer to WARNING and CAUTION labels prior to use.
Keep out from under any raised loads and keep out of

the line of force of any load.
Do not use wire ropes or cables for any purpose other

than which it was intended.
AVOID SHOCK LOADS

Warnings

Failure to use wire ropes or cables properly may cause

loads to slip or fall.
Failure to read, understand and follow these instructions

may cause death or serious injury.
Do not exceed safe working load limits.

OPERATION

DO NOT LIFT, CARRY OR HANG

PUMP BY THE ELECTRICAL CABLE.

DAMAGE TO THE ELECTRICAL

CABLE CAN CAUSE SHOCK, BURNS

OR DEATH.

Raise and lower the pump in the containment area using

the lifting cable attached to the system's quick disconnect

for the A10-12, A10-2015 or A10-20, and to the pump's

lifting eye/strap for the A10-30, A10-40 and A10-60. DO

NOT use electrical cable and DO NOT damage the elec-

trical cables while raising and lowering unit. A10-40 and

A10-60 units can be used in conjunction with a lifting

bail (part # ABAIL2).
To ensure full prime, lower the pump(s) on the slide rails

until fully submerged. Do not engage pump discharge to

the rail discharge connection. Jog the pump motor, one

to two seconds, to purge air from pump casing. Lower

the pump and engage with base.
While the slide rail system mating surfaces are self clean-

ing and contain no sealing devices, a check for leaks at

the initial installation and after each pump removal or

installation is recommended.
While manually controlling the pump and the contain-

ment area inflow, using each pump independently, pump

down the containment area.
Observe the pump, piping and slide rail base discharge

connections for leaks.
If leaks are present, reset the pump and slide rail mat-

ing surfaces and recheck. If this fails to stop the leak,

the pump should be removed and the necessary adjust-

ments made to correct the leak. Leakage will cause longer

operation time, higher costs and may lead to premature

failure of slide rail base discharge connection.

WARNING

Hazardous voltage

can shock, burn or

cause death.

WARNING

Wire rope WILL FAIL if worn-out, overloaded, misused,

damaged, improperly maintained or abused.

Wire rope failure may cause serious injury or death!
Protect yourself and others:
• ALWAYS INSPECT wire rope for, WEAR, DAMAGE or

ABUSE BEFORE USE.

• NEVER USE wire rope that is WORN-OUT, DAMAGED

or ABUSED.

• NEVER OVERLOAD a wire rope.

• INFORM YOURSELF: Read and understand

manufacturer’s literature or “Wire Rope and Wire

Rope Sling Safety Bulletin”.*

• REFER TO APPLICABLE CODES, STANDARDS and

REGULATIONS for INSPECTION REQUIREMENTS and

REMOVAL CRITERIA.*

* For additional information or the BULLETIN, ask your

employer or wire rope supplier.

© 1993, Wire Rope Technical Board

Form No. 193