SAFETY INSTRUCTIONS

TO AVOID SERIOUS OR FATAL PERSONAL

INJURY OR MAJOR PROPERTY DAMAGE, READ

AND FOLLOW ALL SAFETY INSTRUCTIONS IN

MANUAL AND ON PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE

INSTALLATION AND OPERATION OF THIS UNIT

AND MUST BE KEPT WITH THE PUMP.

This is a SAFETY ALERT SYMBOL.

When you see this symbol on the pump

or in the manual, look for one of the fol-

lowing signal words and be alert to the

potential for personal injury or property

damage.
Warns of hazards that WILL cause

serious personal injury, death or major

property damage.
Warns of hazards that CAN cause

serious personal injury, death or major

property damage.
Warns of hazards that CAN cause per-

sonal injury or property damage.

NOTICE: INDICATES SPECIAL INSTRUCTIONS

WHICH ARE VERY IMPORTANT AND

MUST BE FOLLOWED.

THOROUGHLY REVIEW ALL INSTRUCTIONS

AND WARNINGS PRIOR TO PERFORMING ANY

WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.

UNIT NOT DESIGNED FOR USE

WITH HAZARDOUS LIQUIDS OR

FLAMMABLE GASES. THESE

FLUIDS MAY BE PRESENT IN

CONTAINMENT AREAS.

DESCRIPTION and SPECIFICATIONS:

The GB Series pump is a portable horizontal multi-stage
pump designed for residential and agricultural wash-

down, misting and general boosting services.
The 304 stainless steel version of the GB is used for
HVAC, general commercial, reverse osmosis and filtra-
tion applications.

ENGINEERING DATA

Maximum Liquid Temperatures: 160°F (72°C).

Maximum Suction Pressure 75 psi.

Pipe connections are 1" NPT suction and discharge.

¾" Hose Adapters are available.

Capacities to 33 GPM.

Heads to 600 Feet (260) psi.

Rotation: Right hand, ie; clockwise when viewed from

motor end.

DANGER

WARNING

CAUTION

WARNING

Hazardous fluids

can cause fire,

burns or death.

PIPING

Piping should be no smaller than the pump discharge

and/or suction connections. Piping should be kept as
short as possible, avoiding unnecessary fittings to mini-
mize friction losses.

All piping MUST be independently supported and

MUST NOT place any piping loads on the pump.

All joints MUST be airtight. Use 3 – 4 wraps of

Teflon™ tape to seal threaded connections.

WIRING AND GROUNDING

Install ground and wire according
to local and National Electrical
Code requirements.

Install an all leg disconnect switch
near the pump.

Disconnect and lockout electrical
supply before installing or servic-
ing pump.

Electrical supply MUST match pump’s name plate

specifications. Incorrect voltage can cause fire and/
or damage to the motor and voids warranty.

Motors not protected MUST be provided with

contactors and thermal overloads on single phase

motors, or starters with heaters on three phase mo-
tors. See motor nameplate.

Use only stranded copper wire to motor and ground.

The ground wire MUST be at least as large as the wire

to the motor. Wires should be color coded for ease of
maintenance.

Pumps with open spray application must
be plugged into electrical service which is

protected by a Ground Fault Service Interrupter. Failure
to do so may result in serious personal injury or death
and property damage.

Follow motor manufacturer’s wiring diagram on the

motor nameplate or terminal cover carefully.

FAILURE TO PERMANENTLY

GROUND THE PUMP, MOTOR AND

CONTROLS BEFORE CONNECTING

TO ELECTRICAL POWER CAN CAUSE

SHOCK, BURNS OR DEATH.

ROTATION

NOTICE: INCORRECT ROTATION MAY CAUSE

DAMAGE TO PUMP AND VOIDS THE
WARRANTY.

Correct rotation is right-hand, CLOCKWISE when

viewed from the motor end.

To reverse three phase motor rotation interchange any

two power supply leads.

WARNING

WARNING

Hazardous voltage

can shock, burn or

cause death.

WARNING

Hazardous

voltage

Advertising