VII. Cable Chart

3-Phase, Direct Online Starting

Connection

Conductors

Starter

For Canada/USA
SUBCAB xAWG/4

red L1

white L2

black L3

yellow/green ground

SUBCAB xAWG/7

red L1

white L2

black L3

yellow GC**

yellow/green ground

orange T1*

blue T2*

Cable Chart

Single Phase

Connection

Conductors

Starter

For Canada/USA
SUBCAB xAWG/4

red 1

black 2

white 3

yellow/green ground

SUBCAB xAWG/7

red 1

black 2

white 3

yellow GC**

yellow/green ground

orange T1*

blue T2*

* Terminal for connection of thermal contacts in the motor and monitoring equipment.

** GC = Ground Check

SUBCAB is a registered trademark of ITT Flygt AB for electrical cables.