WARNING

WARNING

If people are likely to come into

physical contact with the pump or pumped

media (liquid), e.g on construction sites or farms etc., the

grounded socket must have an additional ground-fault

protection device (GFI) connected. When pumping near a

lake (Jetties, beaches, ponds and fountains etc.) a safety-

distance of at least 65 ft. (20 meters) between people and

the pump is applicable. The pump must never be placed

directly into a swimming pool unless it is shut down for

maintenance. If used in connection with swimming

pools, special safety regulations apply.

LEVEL SWITCH OPERATION

Pump control by use of level switch.

Operation

BEFORE STARTING
Check the oil level in the oil casing.
Remove the fuses or open the circuit breaker and check
that the impeller can be rotated by hand.
Check that the monitoring equipment (if any) works.
Check the direction of rotation. The impeller should

rotate clockwise, as viewed from above. When started,
the pump will spin in the opposite direction to the
direction in which the impeller rotates. See the figure.

STARTING JERK

Installation

Run the cables so that they do not have any sharp bends
and are not pinched.
Connect the motor cable to a grounded power supply.
See “Electrical connections”.
Connect a discharge hose to the threaded discharge
connection. The pump is now fitted with a discharge hub
which may be adjusted to provide either vertical (std.)
or horizontal discharge. Simply remove the (2) hex head
cap screws holding the discharge hub, turn the discharge

hub 180º and reinstall the (2) screws.
Lower the pump into the sump by its handle. Do not
lower with cord.
Place the pump on a base which will prevent it from sink-
ing into a soft sump bottom. Alternati vely, the pump can
be suspended by its handle just above the sump bottom.

NOTICE: WHERE REQUIRED BY LOCAL AUTHOR-

ITIES AN ACCEPTABLE MOTOR-

CIRCUIT SWITCH OR OTHER DISCON-

NECTING DEVICE SHALL BE PROVIDED

AT THE TIME OF INSTALLATION.

NOTICE: AT CERTAIN INSTALLATIONS AND

OPERATION POINTS ON THE PUMP

CURVE THE NOISE LEVEL, 70 DB, CAN

BE EXCEEDED.

Electrical Connections

All electrical equipment must be grounded.

This applies to both pump equipment and

any monitoring equipment. Failure to heed this

warning may cause a lethal accident. Make sure that the

ground lead is correctly connected by testing it.
All electrical work shall be carried out under the supervision
of an authorized electrician.

Local codes and regulations shall be complied with.

Check that the main voltage and frequency agree with the

specifications on the pump data plate.

Make sure that the pump is correctly grounded.