Xylem IM251R01 CentriPro Water System Tank User Manual

Page 3

Advertising
background image

3

TABLE OF CONTENTS

SAFETY GUIDELINES .............................................................. 2

Important Definition ............................................................ 2

SAFETY WARNINGS AND INSTRUCTIONS ............................ 2
FEATURES AND OPERATING CYCLES .................................. 3
The Water Systems Tank Concept ............................................ 3
INSTALLATION PROCEDURES ............................................... 4
Typical Submersible Pump Installation ...................................... 4

Typical Jet Pump Installation .............................................. 4

FEATURES AND OPERATING CYCLES

1. Prior to shipping, the tank

is pressurized to a standard

precharge as defined in

the “OPERATION” part of

this manual.

2.

As water enters the

tank, the air above the

diaphragm is compressed

and its volume is reduced

by the volume of water

that enters.

3.

The pressure in the tank

rises. Water continues to

enter until the pump cut-out

pressure is reached. The

pump shuts off and the tank

is now filled.

4. The pressure in the air

chamber forces water into

the system when a demand

occurs without causing the

pump to operate immediately.

Pressure in the chamber

finally drops to the pump

cut-in pressure, the pump

switch activates the pump and

repeats the filling cycle.

The Water Systems Tank

Concept

The water system tank does more than simply store water. It

helps to protect the system components. A properly sized tank

will provide adequate flow even when the pump is not running. It

saves energy by reducing the number of pump starts. In addition,

the water system tank provides increased system component life

due to fewer pump cycles.

The water system tank consists of a steel tank (A) containing a

sealed-in-place heavy duty diaphragm (B) which separates air

from the water. The portion of the tank where water is stored (C)

is lined to isolate water from the metal tank. This protects the tank

from internal corrosion.

AIR

WATER

MULTIPLE TANK INSTALLATION PROCEDURE ..................... 4
OPERATION .............................................................................. 5
TROUBLE SHOOTING ............................................................. 5

Air Charge in Tank and Pressure Switch Setting ................ 5

Tank Decommision and Disoposal ..................................... 6

NOTES ...................................................................................... 6
WARRANTY .............................................................................. 7

Advertising