INSTALLATION PROCEDURES

MULTIPLE TANK INSTALLATION PROCEDURE

Typical Submersible Pump Installation

FIGURE 1.

1. When replacing an existing water tank, drain-off water and

bleed-off air completely from tank before discarding.

2. Set and position new tank on a firm, level surface with adequate

drainage. Typical installation shown in figures 1 & 2.

3. For best results use new piping; i.e.: Iron, copper, or rigid PVC.

4. If your system is capable of exceeding a working pressure of

125/100 psig (typically submersible pumps), install a pressure

relief valve (rated at 125/100 psig or less, but greater than

turn off pressure) in the system no more than 10 feet from the

tank. The valve should be the same pipe size as the tank outlet.

This is not necessary on tank-mounted jet pump units.

Typical Jet Pump Installation

FIGURE 2.

5. Connect tank to the pump discharge line using the same

size pipe as the pump tap, or larger.

6. The tank should be flushed 5 times prior to household

use, see Operation section.

Water system tanks can be connected together to increase supply

of usable water (drawdown). Two tanks of same size will double

the supply and three tanks will triple the supply. When using a high

capacity pump, the manifold and pressure switch assembly must

be installed in the pipe line as close to center of tanks as possible.

Manifold and main should be 2 times the size of feederline.