2.2 Transportation guidelines

Precautions

WARNING:

• Observe accident prevention regulations in force.

• Crush hazard. The unit and the components can be

heavy. Use proper lifting methods and wear steel-toed

shoes at all times.

Check the gross weight that is indicated on the package in order to se-

lect proper lifting equipment.

Position and fastening
The unit can be transported either horizontally or vertically. Make sure

that the unit is securely fastened during transportation, and cannot roll

or fall over.

HM122_M043_B_sc

2.3 Storage guidelines

Storage location

NOTICE:

• Protect the product against humidity, dirt, heat sources, and me-

chanical damage.

• The product must be stored at an ambient temperature from

-40°C to +60°C (-40°F to 140°F).

3 Product Description

3.1 Pump design

The pump is a multistage, non-self priming pump. The pump can be

used to pump:

• Cold water

• Warm water

Intended use
The pump is suitable for:

• Civil and industrial water distribution systems

• Irrigation (for example, agriculture and sporting facilities)

Improper use

DANGER:
Do not use this pump to handle flammable and/or explosive

liquids.

WARNING:
Improper use of the pump may create dangerous conditions

and cause personal injury and damage to property.

NOTICE:
Do not use this pump to handle liquids containing abrasive, solid, or

fibrous substances, toxic or corrosive liquids, potable liquids other than

water, or liquids not compatible with the pump construction material.

An improper use of the product leads to the loss of the warranty.

3.2 Application limits

Table 1: Pressure and temperature limits

Seal Code 1HM, 3HM

5HM

10HM,

15HM,

22HM

2-6 Stages 7+ Stages 2-5 Stages 6+ Stages All Stages

BQE

147PSI at

248F

235PSI at

248F

147PSI at

248F

235PSI at

248F

235PSI at

248F

BQV

147PSI at

248F

235PSI at

248F

147PSI at

248F

235PSI at

248F

235PSI at

248F

QQE

147PSI at

248F

235PSI at

194F

147PSI at

248F

235PSI at

194F

235PSI at

194F

QQV

147PSI at

248F

235PSI at

194F

147PSI at

248F

235PSI at

194F

235PSI at

194F

BVE

147PSI at

194F

Not Avail-

able

147PSI at

194F

Not Avail-

able

Not Avail-

able

3.3 The data plate

The data plate is a label on the pump. The data plate lists key product

specifications.

1.

Goulds Water Technology Catalog Number

2.

Capacity range

3.

TDH range

4.

Rated speed

5.

Rated horsepower

6.

Maximum operating pressure

7.

Maximum fluid temperature

8.

Pump serial number

IMQ or other marks (for electric pump only)
Unless otherwise specified, for products with a mark of electrical-relat-

ed safety approval, the approval refers exclusively to the electrical

pump.