S-drive typical installation – Xylem IMS SDQ 1 S-Drive Quick Start Up Guide User Manual

Page 2

Advertising
background image

S-Drive Typical Installation

3

FLOW

4

6

5

1

2

8

9

7

L1
L2
L3

GND

T1
T2
T3

GND

10

11

SUPPLY POWER

1 S-Drive Controller

2 Fusible Disconnect

3 Pressure Gauge

4 Air Diaphragm Tank

5 Pressure Transducer

6 3 Phase Output (Always)

7 Discharge Check Valve

8 Gate Valve (Highly Recommended)

9 Submersible Pump End

10 Submersible Motor (3 Phase)

11 Pressure Relief Valve

NOTE: for single phase input, connect L1 and L3, then set motor overload switches to

50% of controller rating or lower.

Xylem Inc.

www.xyleminc.com

© 2011 Xylem Inc. IMS-SDQ-1 December 2011