Wiring Diagram

Foot Strainer

Strainer Adapter

Strainer Body

Screen Strainer

Suction Tubing

Part Number

C-304X

Exploded View

When purchasing the FVS ( Flow Verification Sensor) you will also receive a Foot Strainer (see diagram below). This will
prevent any small particles from entering and clogging the Micro Body.

FVS

Page 4

Sensor

+

_

Red

0v dc

(True digital Square-wave output)

+5v dc

Bare

Black

Ground

Sensor connections:
Input voltage (vdc) 8 to 28 vdc
Output voltage (v) “high state” 4 80 v dc min (5 vdc normal)
Output voltage (v) “low state” 0 2v dc max

(signal output)

Industries, Ltd.

Blue-White

Industries, Ltd.

®

NOTE: Blue-White recommends using the foot strainer part number, C-340X on Peristaltic pumps only.

Diaphragm pumps require a foot valve/ strainer. The part number for the foot valve/ strainer is C-340A.