Xylem Parshall flumes User Manual

Parshall flumes, Installation instructions

Advertising
background image

Installation Instructions

MJK Automation A/S
Byageren 7
DK-2850 Nærum
Denmark
Tel.: (+45) 45 56 06 56
Fax: (+45) 45 56 06 46
[email protected]
www.mjk.dk

MPARGB0204

As our products are developed continuously,
we reserve the right to make any changes without prior notice.

Parshall flumes

It is very important for the overall measuring
accuracy to comply with the installation
instructions on the next page.

At free flow, only the level h

a

is measured.

The location of the sensor is important and
must be carried out as illustrated below. It is
important to have a laminar flow (horizontal
streaming calm water with no whirls) at the
outlet and inlet from the flume, and the outlet
must be unobstructed.

The flume must extend upstream at least ten
times the width of the inlet section of the
flume. On the outlet side the only demand is
that the water should run freely.

The flow is calculated from the formula:

Q = k × h

a

n

where:

Q = flow in m

3

b = throat width
h

a

= water level before the throat [m]

h

b

= water level in the throat [m]

L = distance to the sensor = 3 to 4 × h

a max

The factor k and exponent n are constants. The
formula complies to free flow, h

b

max

< 0,7 × h

a max

General

Table for determination of the constants k, n and the distance
to the sensor.

b

b

b

b

b

k

k

k

k

k

n

n

n

n

n

L

L

L

L

L

2"

425

1,548

0,27

3"

630

1,548

0,30

6"

1310

1,574

0,41

9"

1851

1,528

0,58

12"

2407

1,519

0,89

Q/h diagram for Parshall flumes, the height h

a

is

shown as a function of the flow Q.

Specifications

Size

Q

min

Q

max

H

max

Weight

2 inch

50 mm

10 m

3

/h

100 m

3

/h

393 mm

10.3 kg

3 inch

75 mm

27,5 m

3

/h

275 m

3

/h

591 mm

16.5 kg

6 inch

150 mm

60 m

3

/h

600 m

3

/h

609 mm

33.0 kg

9 inch

225 mm

12 m

3

/h

1200 m

3

/h

753 mm

43.5 kg

12 inch

300 mm

20 m

3

/h

2000 m

3

/h

885 mm

100.0 kg

Material

Fibre glass

pH range

pH 3 - 10

Temperature range

- 20 … +30 °C, for short periods up to 90 °C

1” 2”

3”

6” 9” 12”

24”

36”

Note!