) indication leds, ) troubleshooting – Xylem EHR IM Electrical heater series EHR (obsolete) User Manual

Page 11

Advertising
background image

11

14.) Indication LEDs

Green

Red

Yellow

Main switch on,

on

off

off

no heat request

Pump on,

on

off

on

heat request

Set feed temperature

on

off

blinking

reached

Excess temperature

on

on

off

cut out

13.) Troubleshooting

The EHR series is generally very reliable. If the unit
nevertheless is not operating , first check, whether it is wired
properly and whether the system is filled and properly
primed.

What to do when the unit gives no heat
- check setting and wiring of a room thermostat or timer, if
connected to the unit. The output of the room thermostat or
timer has to be a no loaded one (potential free) and has to
be closed, if heat is required.
- check the temperature setting of the EHR itself.
- If the LEDs show temperature cut out, reset it by pushing
ist knob.(Caution: If a safety temperature cut out has
tripped, you must investigate and correct the cause)

What to do when the heating performance is unsatisfactory:
- check design heating requirement
- check setting of a room thermostat or timer, if connected to
the unit.
- check temperature setting of EHR

Advertising