Adding room thermostat
RTS;
Mains connection on
terminals L and N. Ground
connection on the ground
terminal on the brass
body.Remove jumper wire
between terminals 5 and 6
of the EHR terminals and
connect those to room
thermostat connections 1
and 3.
Adding timer thermostat
RTU;
Mains connection on
terminals L and N. Ground
connection on the ground
terminal on the brass
body.Remove jumper wire
between terminals 5 and 6
of the EHR terminals and
connect those to timer
thermostat connections.
Standard:
Mains connection on
terminals L and N. Ground
connection on the ground
terminal on the brass body.
Leave the jumper wire
between terminals 5 and 6
in place