Specifications installation – Xylem MM 251C Series 750B-C3 Chamber with 3 Probes Series 750B-C4 Chamber with 4 Probes User Manual

Page 2

Advertising
background image

2

4-3/16"
(106.4)

4-3/8"

(111)

A

B

C

D

2-1/2"
(63.5)

3-1/4"
(82.5)

3-1/4"
(82.5)

3-1/8"
(79.4)

1" NPT

11-1/2"

(292)

18-5/8"

(473)

1/2" NPT

1/2" NPT

1/2" NPT

CONDUIT

CONNECTION

1"
NPT

1" NPT

1/2" NPT

ELECTRODE

PRE-CUT

9" PROBE ROD

CUT AS

NEEDED

SPECIFICATIONS

INSTALLATION –

TOOLS NEEDED:
One (1) pipe wrench, one (1) flathead screwdriver and/or 11/32" nut driver,
one (1) metal-cutting saw, and pipe sealing compound.

Maximum Water Temperature: 406˚F (208˚C)
Maximum Water Pressure: 250 psi (17.6 kg/cm

2

)

Maximum Steam Pressure: 250 psi (17.6 kg/cm

2

)

C3

C4

No. of

3

4

Probes

A

X

X

B

X

X

C

X

X

D

X

All probes are cut to 9" length (229mm). Any of these probes can
be used as the low water cut-off level probe. The remaining
probes can be ‘cut to length’ in the field using a metal cutting saw
to achieve desired pump control or additional alarm activation.

Advertising