Caution – Xylem MM 702E Series 14-B Ball Type Blow Down Valve User Manual

Page 3

Advertising
background image

3

h. Using a scraper, remove the old gasket (F)

from the control (A). The gasket sealing sur-
face (G) must be smooth and clean for
proper installation.

G

F

A

e. Using a flathead screwdriver (E),

loosen the four (4) screws.

E

E

f.

Remove the blow down valve (D) from
the control (A). If necessary, use a
hammer to tap it loose.

D

D

A

A

g. Inspect the float chamber (E) for debris.

Carefully remove any debris, mud, or other for-
eign matter which may obstruct the float's full
range of motion, without puncturing the float.

E

OR

OR

To prevent flooding, do not puncture float.

Failure to follow this caution could cause property damage.

!

CAUTION

NOTE: For spring type blow down
valves, the spring mechanism must
be removed from the control body.

Advertising