Xylem PL200-G WATER PRESSURE DATA LOGGER User Manual

Page 4

Advertising
background image

Global Water

800-876-1172

globalw.com

- 4 -

IV.

Specification:


Power Supply:

Two 9VDC alkaline batteries standard

Standby

Current:

65uA

Typical

Logging Current: 5mA Typical + sensor current


Operating Temperature

Industrial, -40ºC to +85ºC (Batteries may not apply)


Analog Inputs:

0-200 psi gauge pressure sensor

300

psi

over-pressure

Accuracy,

+/-

1%,

full

scale

Battery

voltage

monitor

Analog

Resolution:

12-Bit,

4096

Steps

Sensor

Warm-up

Time:

3

Seconds

recommended


Sample Modes:

Fixed Interval: Programmable from 1 Sec. to >1 Year

High Speed: 10 Samples per second

Logarithmic

Sample Rate (Approximation)

Exception

(Log

only

on

deviation from previous reading)


Storage Capacity:

81,759 Recordings of water pressure and battery
voltage with date/time stamp

Communication Ports:

USB Type B
Selectable Baud Rates: Auto detect or fixed rates at
9600, 19200, 28800, 38400, 57600, 115200