WL705 Ultrasonic Water Level Sensor

01-313 5/4/12.doc


Specifications:

Sensor Range:

WL705-003

4” (.33’) - 36” (3’)

WL705-012

4” (.33’) - 144” (12’)

WL705-048

15” (1.25’) - 576” (48’)

Supply Voltage:

10-30VDC (sensitivity reduced below 15 VDC)

Supply Current:

40mA

Averaging Time:

15 seconds

Temperature:

-40º to +158º F Output Current:
4mA, maximum distance
20mA, minimum distance

Connections:

Brown +15-30VDC
Blue

Ground

Green 4-20mA output (WL705-048)
Black 4-20mA output (WL705-012 & WL705-003)

Operation:

The WL705 sensors use ultrasonic sound waves to determine the distance from the face of the sensor
to the surface of the water by timing how long it takes the signal to return. An internal temperature
sensor automatically compensates for the temperature related variation in the speed of sound and a 15-
second averaging time reduces the affects of turbulence in the water. Note that the sensor must be
powered for 15 seconds for the output to stabilize.

WL705-012/003

WL705-048