Appendix a: sample size vs. head height, Appendix b: battery life, Global water – Xylem WS755 IMPROVED WASTEWATER/STORMWATER SAMPLER User Manual

Page 15

Advertising
background image

Global Water

800-876-1172

globalw.com

- 15 -

Actual Sample Size vs. Sample Size Control for Various Head Heights

0

200

400

600

800

1000

1200

1400

1600

1800

2000

0

250

500

750

1000

1250

1500

1750

2000

2250

Actual Sample Size (ml)

S

a

m

pl

e

S

iz

e

C

ont

rol

S

e

tt

ing (

m

l)

Appendix A: Sample Size vs. Head Height

Use the following graph to see how sample size changes with head height. The Sample

Size controls on the control panel are calibrated at a height of 4 feet. Increasing the head

height decreases the sample size by a predictable amount. To determine the appropriate

Sample Size setting for a desired volume; find the sample size on the horizontal axis, follow

straight up to the line corresponding to your head height, then look across to the vertical

axis and read the setting for the Size control on the control panel.

14 Feet

2 Feet

Advertising