Iv. wq750 specifications – Xylem WQ750 TURBIDITY SENSOR User Manual

Page 4

Advertising
background image

Global Water

800-876-1172

globalw.com

- 4 –

Copyright

 Global Water Instrumentation, Inc. 2012

IV.

WQ750 Specifications:


Turbidity Sensor:

Power:

10 VDC to 24 VDC

Current Draw: ~220mA @ 12 VDC

Operating Temperature

0ºC to 50ºC (32ºF to 122ºF)

Analog Sensor Output:

4-20mA Isolated

Signal Filter - 10 Seconds

Measurement Mode:

90º scattered light with pulsed infrared light,

according to ISO 7027 (DIN 38404)

Range: 1 – 1,000 NTU/FNU

Resolution: 12-bit

Operating Pressure:

6 bar (87 PSI) maximum


Timer Module:

Power Requirements:

10 VDC to 24 VDC, 50 mA

Operating Temperature: 0ºC to 50ºC (32ºF to 122ºF)

Sensor Housing:

Material:

Housing: 316 SS

Wiper: Rubber

Sensor Window: Quartz glass

Dimensions:

Diameter: 38 millimeters (~1.5 inches)

Length: 146 millimeters (~5.75 inches)

Process Connection: 1” BSPP

Weight:

0.7kg (1.4 lbs) without cable


Cable:

Conductors:

7 each 22 AWG

Shield:

Aluminum foil/tinned copper wire

Cable length:

13 meters (~42.5 feet)

Advertising