Sample Continuously: Clicking this button causes the Global Access software to

take and display a real-time reading approximately once per second until stopped by

clicking it again. Each sample will also update the rest of the fields on the logger's

window. These data readings are not stored in the historical record and do not affect

the normal recording of the logger. The initial reading has a sensor warm-up time of

50mS and the sensor is left powered up until this feature is turned off. In this mode

power is continuously applied to the sensors. This may cause the warm-up time to

not be enforced for a scheduled sample if the logger determines that power has

been applied for a period greater than or equal to the warm-up time.

Signal Level: A window opens to display the

received signal strength of the selected radio

modem. This is generally for quick reference

only. A more accurate measurement can be

made using diagnostics software available from

Global Water.

Click the Next Radio button to cycle through all

active radios one at a time. Click Exit to close

the signal level window and go back to the

main screen.

Get History: This button starts the transfer of all the historical data stored in the

logger’s memory to the PC. Oldest data is collected first and Clicking “Stop” halts the

process.

Clear History: This resets the number of recordings in memory to zero. The user is

warned first and must confirm the action before the memory is cleared.

Sync Time: This button causes the data logger’s internal clock to be set to the

system time of the computer it is connected to. The user is warned first and must

confirm the action before the time is set.

Setup: Clicking this button enters the setup screen where the user can change and

program all parameters into the data logger. Details of the Setup menus are not

described here. For more information on this function, see the software help files or

consult the manual supplied with the data logger.